| Place of Origin |
Zhejiang China (Mainland) |
| Brand Name |
CSR |
| Model Number |
NT4-P |
Application: For the electronic measurement of currents: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high power) and the secondary (electronic) circuits. Main electrical data: 1.Primary nominalcurrent IPN: 4A rms 2. Measuring range IP: 0 ±6A 3. Secondary nominal output: 1.65V ± 0.833V 4. Ratio: 1: 1500 5. Supply voltage:+3.3×(1±5%)V 6. Isolation:Between primary and secondary: 3kVrms/50Hz/1min Accuracy – Dynamic performance data: 1. Accuracy @ IPN,TA=+25ºC:±1% 2. Non-linearity: TA=+25ºC:≤±0.2% 3. Offset of zero current: ≤1.65V±0.025V (+25)ºC 4. Thermal drift:@ -25ºC +85ºC: ≤300ppm/ºC 5. Response time:@90% of IPN:≤400ns 6. di/dt accurately followed:> 15A/us General data: 1. Operating temperature:-25ºC +85ºC 2. Storage temperature:-40ºC +100ºC 3. Weight:10g±2g 4. Standards:EN50178:1997 Features: 1. Zero magnetic flux Hall effect principle 2. Galvanic isolation between primary and secondary circuit 3. White PPO-made plastic shell meet the requirements of UL 94-VO 4. The current transducer meets the requirements of RoHS Directives